Product Details:
| Current Rating | 32A |
| Dimensions (mm) Overall (L x W x D) | 96x96 |
| Voltage | 220–240V AC, Single Phase |
| Country of Origin | Made in India |
| Operating Voltage | 220V–415V AC (single-phase or three-phase, depending on model) |
| Current Range | 5A to 32A (adjustable overload settings) |
| Protection Types | Overload, Dry Run, Phase Failure, Reverse Phasing, Unbalanced Voltage |
| Starter Type | Compatible with DOL and Star-Delta starters |
| Enclosure | IP65 plastic/metal casing (dust & water resistant) |
| Indicators | LED/digital display for motor status |
| Control Options | Auto/Manual reset, emergency stop |
| Applications | Submersible pumps, agricultural motors, industrial |
Product Details:
| Motor Power | 0.5 HP |
| Rated Voltage | 220 V |
| Starter Type | Star Delta |
| Voltage | 415 V |
| Phase | Single Phase |
| Automation Grade | Automatic |
| Power Rating (kW) | 7A, 230 VAC |
| Usage/Application | Industrial |
| Brand | VENEX |
| Ambient Temperature | 0°C ~ 55°C |
| Country of Origin | Made in India |
Inputs:
Voltage input: R, Y, B phases (10 VAC ~ 650 VAC)Outputs:
Relay: 3CO (Main, Star, Delta)Operating Conditions:
Temperature: 0°C ~ 55°CProduct Details:
| Motor Power | 3 kW |
| Rated Voltage | 415 V |
| Starter Type | Star Delta |
| Phase | Three Phase |
| Mounting Type | Panel Mount |
| Enclosure Type | MS Powder Coated, Stainless Steel, IP42, IP65, Weatherproof, IP55, Sheet Metal, CRC Sheet, FRP, IP54 |
| Control Supply | 230 V AC |
| Application | Blower, Crusher, Conveyor, Industrial Plant, Pump, HVAC, Compressor, Elevator |
| Brand | Other Make |
| Ambient Temp | 40 Deg C |
Protection Functions:
Phase sequence monitoring (ensures correct rotation)Operation Modes:
Automatic star‑to‑delta transition after preset time delayProduct Details:
| Type | Relays |
| Protection Class | Type 1 |
| Rated Voltage | 230 V |
| Maximum Discharge Current (Imax) | 100 kA |
| Number of Poles | 1 Pole (1P) |
| Nominal Discharge Current (In) | 10 kA |
| Application | AC Power Line |
| Mounting Type | DIN Rail |
| Voltage Protection Level (Up) | <1.5 kV |
Inputs:
CT input (50A CT, range 1.0–50.0A)Outputs:
Protection:
Overload (OL)Controls:
SET, UP, DOWN, RESET, AUTO/MANUAL keysProduct Details:
| SPD Type | Type 2 |
| Rated Voltage | 230 V |
| Voltage Rating | 230 VAC, 50Hz, ±10% |
| Maximum Discharge Current (Imax) | 40 kA |
| Poles | 2 Pole |
| Protection Class | IP65 |
| Max Discharge Imax | 100 kA |
| Mounting | Panel Mount |
| Remote Signalling | Without Remote |
| Replaceable Module | Yes |
Relay Outputs:
1 relay for StartFunctions & Protections:
Overload protection